Lateral Stability KL = 1 Setting (v8.31 - Bug 2105)

The following changes have been made to the operation of the Design Setting Assume KL = 1, which is checked if the member is laterally supported according to the conditions in CSA O86 5.5.4.2.1 so that computation of lateral stability KL using 6.5.6.4 is not necessary.

Default Value

The program now sets the original “factory” default for Assume KL = 1 to be unchecked rather than checked. You can change this via Save as Default.

Note in Beam View

If Assume KL = 1 is checked, a note has been added to the Lateral support section in Beam View that says "Used when b/d > 9 (5.5.4.2.1)".

Design Results Output

When checked, and b/d is not greater than 9, the lateral support inputs are no longer displayed in the design results output

In This Section

Project Settings Saved As Default (v8.31 - Bug 2255)

XML Transfer of Steel Sections (v8.3 - Change 123)

Design Search Failure Warning after XML Transfer (v8.3 - Change 124)

XML transfer of Version Info (v8.3 - Change 125)

XML Transfer of Combined Axial and Bending Results (v8.3 - Change 126)