Final Design Check

Important Note – These are descriptions to changes implemented in WoodWorks Shearwalls for version 9 and may not reflect current behavior.

  1. Structural Design Check

    For the entire structure, forces are distributed based on the capacities, stiffnesses, and shear resistance distribution of the walls designed on the second per-level iteration and the r value from the second structural iteration, if one was needed.

    The designed walls are then checked against the new forces, and the results reported in the Design Check output. :

  2. Reasons for Check
    1. Output Report Consistency

      This ensures that the output reports show the force distribution, the r value, the shearwall deflection, and shearwall design capacity from the same set of walls.

    2. Possibility of Failure

      Although it rarely occurs, it is possible that the walls designed on the second iteration cannot withstand the forces created from their rigidities. The design check shows this situation, indicating to the user via the following warning message that the problem is to do with design iterations and can be remedied by more manual input.

Warning: For shearline(s) [ A, B, C, ..., 1, 2, …], a shearwall that passed the design check on the initial run failed the final check when forces were redistributed to shearlines and/or wall segments within a line using [ shearwall deflection, shearwall capacity]. Try to adjust wall materials to achieve a passing design, or choose a different force distribution option in the Design Settings.

See Also

Shearwall Design Iterations

Previous Versions

Design Iterations Per Level

Structural Iteration for Redundancy Factor

Progress Bar