Important Note – These are descriptions to changes implemented in WoodWorks Shearwalls for version 10.2 and may not reflect current behavior.

  1. Input of Invalid Wall Location (Bug 2754)

    Changing the location of a wall via the input field in the Wall Input dialog of a wall to a location that was invalid because it is outside the building perimeter, intersects with another wall, etc., caused the program to crash. The program now shows an error message and does not allow the wall to be made.

  2. Subtract Hold-down Offset From Moment Arm Setting (Bug 2731)

    The hold-down setting to subtract the hold-down offset from the overturning force moment arm operated in reverse, that is, when you selected that the offset was to be subtracted, it didn’t subtract, and vice-versa. This has been corrected and the program subtracts the offset when you indicate so in the settings.

  3. Eccentricity of Wind Loads in Site Information Dialog (Bug 2717)

    In the Site Information dialog, when the Dynamic analysis checkbox was unchecked, pressing the Estimate button caused the Eccentricity values to change unexpectedly. Eccentricity for north-south loads was reduced by a factor of 100 and for east-west loads by about 1000. These values were retained and used for design if they are not changed back.

  4. Display of Failed Walls due to C&C Design (Bug 2732)

    When walls fail due to C&C design only, the note in plan view said that it fails for flexible wind design; however, flexible distribution is not relevant to C&C design. This has been corrected by indicating that it fails for C&C design instead. If it fails for both C&C and MWFRS design, both are indicted in the note.

  5. Default Setting for Save as Default (Change 159)

    The default setting for Save as default for new files for Default Values and Company Information settings has been changed from being unchecked by default to being checked by default.

  6. Reporting of Wall Segment Shear Force V for Openings at Start of Wall (Bug 2721)

    When a wall has an opening positioned at the start of the wall with zero offset, the total Shear Force V reported for the next wall segment was incorrect in a random way. This was a problem with the output report only; the correct value is used in design. The correct shear value V now appears in the output report.

  7. Shearwall Wall and Opening Dimensions Table Legend (Change 162)

    The Shearwall Wall and Opening Dimensions table legend has been updated to make it more readable and fix minor typos. Each item now appears on a separate line, similar to other legends. Improved explanations are given for wall groups and wall length.

  8. Crash on Results Output for Windows 8 (Bug 2758)

    For some Windows 8 systems, for any building, even a simple rectangular building with no openings, after pressing the design button and when the progress bar indicated that the program is outputting results, the program crashed. This no longer occurs for version 10.2.

  9. Plan View Update Quality (Change 161)

    The plan view now draws more smoothly without flashing on changes or when scrolling

  10. Appearance of Load Arrows (Bug 1952)

    For large structures, the arrows in Plan View representing applied loads became much more widely spaced than for smaller structures, and the arrowhead was not visible. This has been corrected and the appearance of the load arrows is similar for large and small structures.