This version released July 17 2012 as a hot fix directly to the user(s) with the following problem:
When there are openings or non full height sheathing on a shearline and the forces distributed to the wall segments use the "Equal Rigidities” setting, or equivalently, the distribution to wall segments setting is not based on rigidity, then the total force on a wall segment V reported in the Shear results table is incorrectly based on the total length of the wall rather than the full height sheathing. The forces shown are thus heavier than expected, and they do not add up to the total force on the shearline, which is reported correctly.
This affects output only; the incorrect forces are not used for design or for collector force calculations and the correct segment forces appear in elevation view.