Important Note – These are descriptions to changes implemented in WoodWorks Shearwalls for version 10.0 and may not reflect current behavior.
The program now allows input of 19.2” stud spacing, corresponding to 1/5th of the length of a standard sheet of plywood. When 19.2” is selected, the program uses the unblocked factor in SDPWS Table 4.3.3.2 for maximum 20”.