Location and Scale in Point of Interest View Drawing (v9 - Bug 2782)

The location of the dot in the point of interest view and the scale drawn at the bottom did not properly take into account the input span methodology, and were shifted relative to the actual values by the ½ the width of the support for full span and clear span inputs. This has been corrected.

See Also

Loads and Loads Analysis

Automatic Eccentricity of Axial Loads (v9 - Feature 17)

Different Eccentricity for Each Load (v9 - Feature 18)

Importance Factor for Part 9 Snow Loads (v9 - Feature 206)

Importance Category Output (v9 - Change 157)

Default Pattern Load for Roof Joists based on Slope (v9 - Feature 162)

Tributary Width Message Box (v9 - Feature 196)

Applied Moments at End of Full Span (v9 - Bug 2845)

Point Loads at Left End of Rightmost Support (v9 - Bug 2857)

Combining Concentrated and Sustained Live Loads (v9 - Bug 2833)

“Construction” Load Instead of Live Load (v9 - Bug 2852)

Analysis Diagram Dimension Lines (v9 - Bug 2719)

Tributary Width in Load Table