Design Search for Combined Axial and Bending (v8.2 - Bug 2610)*

Starting with Sizer version 8, the program examined only the first section in a design search for the combined axial and bending criterion. The check was skipped for the rest of the sections skip the check, so that if they failed for combined axial and bending, they were still considered passing sections. If such a section is selected for a design check, the combined axial and bending check is done and the section fails.

In the Design Summary, the design ratio reported for combined axial and bending was zero for all but the first section. 

This has been corrected and the combined axial and bending check is done for all sections with results shown in the Design Summary..

See Also

Beam and Column Engineering Design

Beam and Stringer Grades for Post and Timber Sizes (v8.2 - Bug 2588)

LVL Columns (v8.2 - Change 121)

Glulam Shear Load Coefficient Cv Calculation (v8.2 - Bug 2568)

Structural Composite Lumber Lateral Stability Factor KL (v8.2 - Bug 2586)

Combined Axial and Bending Results for High Pf/Pe (v8.2 - Bug 2587)

Secondary Moment Check Warning (v8.2 - Bug 2587)

Axial Compressive Resistance fc for Sloped Custom Section Beam Bearing Design (v8.2 - Bug 2597)

Vibration Design for Custom Floor Joist Sections (v8.2 - Bug 2545)

Small Point Load Bearing in Absence of Point Loads (v8.2 - Bug 2607)

Point Load Bearing Design Note (v8.2 - Change 119)

Span Input Corruption for Long Spans (v8.2 - Bug 2455)

Maximum Shear within Span Warning for Lightly Loaded Spans (v8.2 - Bug 2486)