Important Note – These are descriptions to changes implemented in WoodWorks Shearwalls for version 9 and may not reflect current behavior.
The program now implements the new provisions in SDPWS 4.3.3.2 for blocked structural panel walls.
The program now allows you to select Unblocked for a wall sides with the following configuration:
Structural I and Structural sheathing can now be unblocked. Plywood siding materials cannot be unblocked.
If Unblocked is selected, the panel edge spacing is limited to 6”.
Unblocked is unavailable for walls greater than 16’ in height. A wall changed to that height will cause an unblocked wall to be blocked.
Structural sheathing with gypsum underneath cannot be unblocked, as SDWPS 4.3.3.2. refers to Table 4.3A only, not to table 4.3B for gypsum underlay.
Changing the blocking selection for multiple walls is now possible. Previously the program disabled the selection when multiple walls were selected.
The program applies the Cub factor from Table 4.3.3.2 based on stud spacing and intermediate (field) nail spacing to the capacity of the sheathing on each side of the shearwall independently.
The 20” stud spacing option is not implemented for this version of Shearwalls. The Cub factor is applied for the existing choices of 12, 16 and 24”.
For values of intermediate nail spacing between 6 and 12”, the factor for 12” spacing is used, in other words, the program does not interpolate Table 4.3.3.2.
SDPWS 4.3.2.2 calls for the unit shear value v in the three-term deflection equation 4.3-1 to be divided by Cub. Equations 4.3.2.2-1,2 show that this is equivalent to dividing the first two terms in the equation (bending and combined shear/nail slip) by Cub.
Shearwalls uses the more accurate 4-term equation from C4.3.2-1, so the program divides the first 3 terms of the equation (bending, shear, and nail slip) by Cub. This is the equivalent procedure to that prescribed for the 3-term equation.
Note that the program does not divide v by Cub in the calculation of en for the nail slip term. The calculations of hold-down forces used in the 4th term also do not involve division by Cub.
For seismic design, the Cub factor is shared with a column that was originally for the seismic height-to-width factor for structural materials, but is now also shared by the fiberboard height-to-width factor. It is now called HW-Cub.
Note that because unblocked walls are restricted to a H-W ratio of 2, and because fiberboard does not have a Cub factor, it is impossible to have a combination of these factors, the factors shown will be one of the three.
For wind design, the value of Cub for exterior and interior side of a wall is shown in a similar column that has been added for this and for the fiberboard height-to-width factor. The low-rise load case has been removed from the table to make space for it.
The unit shear force v shown in the Deflection Table is v divided by Cub. The force Vn per fastener has not been divided by Cub.