The table below lists the design code provisions from the AWC Special Design Provisions for Wind and Seismic (SDPWS) applicable to following aspects of shear wall assembly
for all sheathing material types included in Shearwalls.
.
Wall Construction |
||
---|---|---|
|
Shearwalls |
SDPWS |
Reference |
|
Tables 4.3A-D, 4.3.7.1,4-9 |
|
|
|
Stud spacing |
||
Wood Structural Panels |
||
For shear |
12,16,19.2, 24 |
Max 24" - 4.3.7.1 (5) , Table 4.3A, Table 4.3.3.2* |
For bending strength |
12,16, 24 |
Table 3.2.1 |
Fiberboard |
||
Spacings included |
12,16 |
16 Max - 4.3.7.4 (5) , Table 4.3A |
Lumber Sheathing |
|
|
All |
12,16,19.2, 24 |
Doesn’t say |
Plaster & Gypsum |
||
(for more information, see Table for Gypsum and plaster) |
||
Reference - Gypsum |
|
Table 4.3C |
Wire lath, plaster |
12, 16 |
16” max |
Gypsum lath |
12, 16 |
16” max |
Gypsum Sheathing |
max 16 or 24” |
|
Gypsum Wallboard |
max 16 or 24” |
|
* 19.2 Size included for 20" option in Unblocked Adjustment Factor table 4.3.3.2 |
||
Sheathing Orientation |
||
Wood Structural Panels |
||
For shear strength |
Horizontal or Vertical |
Both - 4.3.7.1 (1) |
For bending strength |
Horizontal or Vertical |
Both - Table 3.2.1 A |
Fiberboard |
|
4.3.7.4(1) |
Allowable orientation |
Horizontal or Vertical |
Horizontal or Vertical |
Lumber Sheathing |
|
Table 4.3D |
Orientation included |
Horizontal, Vertical, Diagonal, or Dbl. Diag. |
Horizontal, Vertical, Diagonal, or Double diagonal |
Plaster & Gypsum |
|
4.3.7.5.1-4 |
Wire lath, plaster |
Blank* |
n/a |
Gypsum lath |
Blank* |
Horizontal |
Gypsum sheathing |
Blank* |
Horizontal or Vertical |
Gypsum wallboard |
Blank* |
Horizontal or Vertical |
*Left blank because it is irrelevant to design |
||
|
||
Blocking |
||
Wood Structural Panels |
|
4.3.7.1 (1) |
All |
Blocked or Unblocked |
Blocked or Unblocked |
Fiberboard |
|
4.3.7.4 |
All |
Blocked |
Blocked |
Lumber Sheathing |
|
4.3.7.6-.9 |
Vertical |
Blocked |
"Applied to studs and blocking" |
All others |
Unblocked |
Not applicable |
Gypsum |
|
T4.3C |
Wire lath, plaster |
Unblocked |
Unblocked |
Gypsum lath |
Unblocked |
Unblocked |
Gypsum Sheathing* |
see Gypsum Provisions * |
Either, Blocked, or Unblocked |
Gypsum Wallboard* |
see Gypsum Provisions * |
Either or Blocked |
*Whether the material must be blocked or unblocked or can be either depends on size, stud spacing, and orientation ) |
||
|
||
Sheathing surface |
||
Plywood |
Either or both |
Either or both |
Fiberboard |
Either or both |
Doesn’t say |
Lumber sheathing |
Either or both |
Either or both |
Gypsum materials |
Either or both |
Doesn’t say |
|
||
Gypsum Wall Board Underlay |
||
with Plywood |
1/2" or 5/8" GWB |
Table 4.3B |
2-ply GWB |
5/8" GWB only |
Table 4.3C |
with other materials |
Not included |
Not included |