Earthquake Loads (Feature 106)

Earthquake loads and the associated load combinations have been added to Sizer version 9 USA.

In Beam Loads view, Column Loads view, and Concept Mode loads view, the load type Earthquake is appended to the existing list of loads, for beams, columns, and in concept mode. It is available for all distributions.

The load type symbol E = earthquake has been added to the one-line legend in Analysis and Additonal Data.

The program includes those load combinations those derived from varieties of live loads like Impact loads and Live roof loads

The load combinations are shown as e.g. D + .75 (S + L + .7E), not D + .75 ( S + L ) + .525E. This corresponds to the D + .75 ( S + L) + .75 (0.7E) combination in ASCE 7 design code.

It appears in

Analysis report list of combinations

All design criteria are examined for earthquake loads, including deflection design..

For Load Duration factor CD , the program continues to use the Ten minutes Wind/Seismic input for both wind and earthquake loads, it does not allow independent input of Load Duration factor in loads view for wind and seismic. Note that NDS recommends the same factor - 1.6. (Table 2.3.2)

In the loads diagram in beam and column view, the colours used for each load type have changed. Impact, roof live and live loads are shown as varying shades of green as they are varieties if live loads. Earthquake loads are coloured dark purple.

See Also

Loads and Analysis

Adding Moments Directly to Members (Feature 20)

User-defined Default Loads

Factor for Area Load on Continuous Support (Feature 63)

Components of Reactions in Design Report (Feature 137)

Column Lateral Reactions (Change 60)

Effect of Point Loads on Vertical Reactions in Analysis Table (Change 38)

Beam View Load Drawing (Changes 42,48)

Column Mode Load Drawing (Bug 2170, Change 42)

Eccentric Axial Load Notes In Analysis Results and Diagram (Change 46)

Vertical Reaction Table for Concentrated Load (Bug 2141)

Validating Partial Line Loads (Change 44)

Concentrated Live Load Default Name (Change 37)