Shear Results Output for Shearlines which Extend over Part of Structure (Bug 2822)

The program outputs only one line of shear results data when there is only one shearwall on the line, on the assumption that the information for the line will be identical to that for the wall. However, when the shearline does not extend the whole distance between exterior walls, the shearline length is different than the wall length. The V/L value shown is that for the shearline, that is, the diaphragm shear flow, and not the design shear flow that is needed for the wall. The design ratio therefore does not correspond to the force V/L and the resistance Vr/L values shown in the line.

See Also

Panel Marking in Sheathing Materials Output (Bug 2808)

Cumulative Storey Shear in Seismic info Table (Change 137)

Shearwall Wall and Opening Dimensions Table Legend (Change 162)

Output of Bx for Torsional Irregularity (Change 154)

Design Code Clause in Irregularities Table (Change 152)

Default Design Results View (Change 155)

Code reference for Gust Effect Factors in Log File (Change 166)

Blank Page in Output (Change 157)

Log File for Torsional Analysis Changes (Changes 138-141)

Capitalization of Load Case (Changs.142)

Component and Cladding Tables Design Tables (Bug 2885)