Building Model Assumptions

Irregularities

ASCE 27.1.2 (Directional method) and 28.1.2 (Envelope method) require that buildings to be regular shaped as defined in 26.2 as having no unusual geometric irregularity. The program does no checking for unusual irregularities - this is the responsibility of the designer.

Shadowing

In the Load Generation input form, the program offers you the option of discounting the redundant loads that are created when one building roof surface is in front of another. Figure 1 shows this situation.

If this option is selected, the program splits the roof surface up prior to generating loads and uses the portions as the recipients of the wind pressures that are converted to loads.

If this option is not selected, the program calculates loads on the entire rearward roof panel despite the fact that a portion is sheltered from the wind. You may want to do this if you prefer a less cluttered load profile even if it results in conservative wind loading.

Figure 1

Note that this option does not apply to the shadowed potion of a wall - it is always discounted automatically by Shearwalls. Also note that if a wall is behind another building element as pictured in Figure 2, loads will be generated for both walls, as is required by all wind load standards.

Figure 2

Monoslope Roofs

Monoslope roofs can be entered, but the portion of the higher wall from the opposite eave elevation to the peak will be treated as a roof panel rather than a wall. On the windward side this means that the mean roof height will be used to evaluate coefficients rather than the actual height. Depending on the design code employed, conservative Cp coefficients are used. As wind loads vary only slightly with elevation, this creates only minor differences in wind loads.

Arched Roofs

The special provisions for arched roofs have not been included.

Mansard Roofs

Mansard roofs cannot be modelled by Shearwalls.

Hip Roofs

When determining the wind pressures on hip roof ends, for the All Heights procedure procedure, ASCE 7 Figure 27.4-1 applies to either a side panel or a hip end.

For the low-rise method method, you have an option in the Site Dialog to treat them the same way as side panels, as was described in the 2001 USA Wood Frame Construction Manual and in the 2002 edition of the ASCE 7 standard, or to use ASCE 7-10 figure C28.3-2.

If they are treated as side panels, the angle of the hip end slope is used for the determination of pressure coefficients. Zone 1, 2, 3, and 4 coefficients are applied, the end zone width is doubled, and Case A and Case B wind directions are both considered, as if the hip roof portion was a side panel. This is true for wind loads on the hip end walls as well as the hip construction side panels.

Overhangs

If overhangs are entered, wind loads are generated for the portion of the roof panel at the overhang, and for the wall surface that is shadowed by the overhang. No special loads are created on the underside of the overhang, as Shearwalls does not generate uplift loads.

Parapets

Shearwalls does not model parapets or generate parapet loads; loads representing the effect parapet pressures must be entered manually.