The table below lists the design code provisions applicable to design for wood structural panel sheathing from the AWC Special Design Provisions for Wind and Seismic (SDPWS) and the ASCE 7. One column is for the design code provision, the other is for the implementation in Shearwalls; in most cases they are the same.
Wood structural panels include the Structural Sheathing, Structural 1, and Plywood Siding materials. They are made of plywood or OSB, which is specified by a check box in wall input view. Design properties are identical for plywood and OSB; some parameters affecting deflection are influenced by the choice.
For some provisions, more detailed information is found in a table dedicated to the provision in another topic that is cross-referenced in this table.
Wood Structural Panels |
||
---|---|---|
|
Shearwalls |
SDPWS / ASCE 7 |
Main References: SDPWS 4.3.7.1, SDPWS Tables 4.3A and 4.3B
|
||
|
||
Wall Construction |
||
(for more details, see Wall Construction ) |
||
References |
|
4.3.7.1. Table 4.3A, Table 4.3.3.2*, Table 3.2.1 |
Sud Spacing shear |
12,16,19.2, 24" |
Max 24” |
Max stud spacing bending |
12,16, 24 |
Table 3.2.1 |
Stud Thickness, nominal |
Default 2" |
2” |
Orientation - shear |
Horizontal or Vertical |
Both - 4.3.7.1 (1) |
Orientation - bending |
Horizontal or Vertical |
Both - Table 3.2.1 A |
Blocking |
Blocked or Unblocked |
Blocked or Unblocked |
Surface |
Either or both |
Either or both |
Gypsum underneath |
Allowed |
Yes |
* 19.2 stud spacing included for 20" option in Unblocked Adjustment Factor table 4.3.3.2 |
||
Sheathing Thickness and Type |
||
Plywood shear |
|
Table 4.3A, |
All materials |
5/16, 3/8 |
5/16, 3/8 |
Structural I and Plywood sheathing |
also 7/16,15/32, |
also 7/16, 15/32 |
Plywood sheathing |
also 19/32 |
also 19/32 |
Plywood siding |
5/16, 3/8 only |
5/16, 3/8 only |
|
|
|
Plywood Bending |
- |
Table 3.2.1 |
Plywood sheathing |
5/16*,3/8,7/16,15/32,19/32, 23/32 |
3/8,7/16,15/32, 19/32, 23/32 |
Plywood siding |
5/16, 3/8 |
Doesn't say |
*5/16 values taken from the Wood Frame Construction Manual. |
||
|
||
Fastener Types and Sizes |
||
(for more details, see Table for Fastener type and lengths) |
||
Common nail |
6d,8d,10d,16d* |
6d,8d,10d |
Box nail |
6d,8d,10d,16d* |
6d,8d,10d |
Galvanised casing |
6d,8d |
6d,8d |
*16d size included for nail withdrawal calculations |
||
|
||
Fastener spacing |
||
(for more details, see Table for Fastener spacing) |
||
Edge spacing |
2,3,4,6” |
2,3,4,6” |
Intermediate Spacing |
2,4,6,8,10,12”* |
6” or 12” max |
*Lower than maximum intermediate spacing values are provided for nail withdrawal resistance |
||
|
||
Seismic Information |
||
Allowable Design Categories |
|
ASCE-7 Table 12.2-1, |
65 Feet or less |
Allows all |
Allows all |
Greater than 65 feet |
Screen warning for D, E, F |
Disallows D, E, F |
|
|
|
Framing detail: For capacity >350 on either side |
Note 1 in Framing Materials Table |
4.3.7.1(5.c) |
Applicable zones |
D,E,F |
D,E,F |
|
|
|
Response modification factor R |
Input in Site Dialog, Prompts to change upon load generation |
ASCE-7 Table 12.2-1, 12.8.1.1 |
R - bearing walls |
Default 6.5 |
6.5 |
R - building frames |
Default 7.0 |
7.0 |
Deflection amplification factor Cd |
Input in Site Dialog, Prompts to change upon load generation |
ASCE-7 Table 12.2-1, 12.8.6 |
Cd - bearing walls |
Default 4.0 |
4.0 |
Cd - building frames |
Default 4.5 |
4.5 |
Overstrength Factor W0 * |
Cannot be overriden |
ASCE-7 Table 12.2-1, inc. note b; 12.10.1.1. |
W0- bearing walls, rigid diaphragms |
3.0 |
2.5 |
W0- building frames, rigid diaphragms |
4.5 |
4.5 |
W0 - bearing walls, flexible diaphragms |
4.0 |
4.0 or 4.5 |
W0 - building frames, flexible diaphragms |
3.5 |
3.5 or 4.0 |
*for drag strut force from discontinuous shear lines above, only |
||
|
||
Permissible Force Distribution Method |
||
Refer to Shear Force Distribution Methods for more a description of these methods and how they are selected. |
||
Reference |
|
SDPWS 4.3.3.4.1 , inc. Exception 1 |
Deflection-based distribution |
Allowed, no reduction applied |
Allowed |
Capacity-based distribution |
Aspect ratio adjustment applied to narrow segments, see below |
Allowed with reduction in capacity for narrow segments |
|
||
Aspect Ratios and Capacity Adjustment |
||
Aspect ratio - h/b, bs = segment length, h =height Applies to wall segments or force-transfer piers. ( For more details see Aspect Ratio Limits and Factors ) |
||
Maximum aspect ratio |
|
SDPWS 4.3.4, Table 4.3.4 |
Blocked, unadjusted |
3.5:1 |
3.5:1 |
Blocked, unadjusted |
2:1 |
2:1 |
Unblocked |
2:1 |
2:1 |
Shear Capacity Adjustment* |
|
SDPWS 4.3.4.2, 4.3.3.4.1 Exception 1. |
Capacity-based force distribution |
2b,/ h |
2b, / h |
Deflection-based distribution |
1.25 - 0.125 h / b, |
1.25 - 0.125 h / b, |
*Applies to segmented and force-transfer walls only; for perforated walls the lengths of the wall segments are factored by 2b,/ h in the calculation of Co . This has the effect of decreasing Co . which is applied to the shear capacity. |
||
|
||
Shear Capacity Adjustments and Notes |
||
Reference |
Notes under Sheathing Materials Table |
SDPWS Table 4.3A Notes, 4.3.7.1 , 4.3.3 |
increase 3/8, 7/16 to values for 15/32 for spacing >= 16" and horizontal orientation |
Note 3 |
Note 2 |
3” framing, staggered nails for certain conditions |
Note 2 |
4.3.7.1 (5) |
Specific Gravity (G) factor = |
1 - ( 0.5 - G) |
1 - ( 0.5 - G) |
Note for G |
Note 1 |
Note 3: |
Wind Increase Factor* |
1.4* |
Incorporated in Table 4.3A |
ASD Reduction Factor** |
Values in Table 4.3D divided by 2.0. |
2.0 |
Note for ASD Factor |
No note |
Note 1 referring to 4.3.3 |
Aspect Ratio Factor |
See above section |
See above section |
*Shearwalls multiplies seismic resistances from Section A the table by 1.4 for wind design. The values may be slightly different than those in Section B of the table due to rounding. |
||
|
||
Gypsum Underlay |
Allowed |
Table 4.3B |
|
||
Combination of Sheathing Capacities |
||
For more details, refer to Combination of Sheathing Capacities, |
||
Reference |
|
SDPWS 4.3.3.3 |
Identical materials on both sides, seismic or wind |
Add capacities |
Add capacities |
With wood structural panels with different specs on other side, wind |
Vwc=Kmin Gac |
No guidance |
With wood structural panels with different specs on other side, seismic |
Vsc =Kmin Gac |
Vsc =Kmin Gac |
With non-wood-structural panels on other side, seismic |
twice weakest or strongest |
twice weakest or strongest |
With lumber sheathing or fiberboard on other side, wind |
twice weakest or strongest |
twice weakest or strongest |
With gypsum wallboard on other side, wind |
Add capacities |
Add capacities |
|
|
|
Bending Resistance |
||
Reference |
|
SDPWS Table 3.2.1 |
5/16” thickness |
Uses WFCM |
Not included |
All other sizes, spacings |
Uses SDPWS |
From Table 3.2.1 |
|