Released December 22, 2016 with Design Office 11, SR-a to address the following problems:

  1. Sporadic Failure of 3-Term Deflection with Non-FHS Segments (Bug 3209)

    When the setting "Rigidity for shear force distribution based on… is set to use the deflection of wall segments and the 3-term equation is selected for the SDPWS deflection equation setting, and there are non-full-height sheathing segments present, sometimes the forces were distributed in an inconsistent and unpredictable manner from one design to the next. This affected the distribution of forces along the shearline, the distribution of forces to the shearlines for the rigid distribution, and ultimately shearwall design. This issue was due to random problems with memory allocation in the computer, and has been resolved.

  2. Disregard Height -to-width Limitation Setting in Files from Previous Versions (Bug 3208)

    For projects made with previous versions to version 11, if the Disregard shearwalls height to width limitations had been set, the Plan View and Elevation View elements relating to aspect ratio did not appear, and upon design the program issued a Windows error message and froze.

    This setting was removed for v11, but if you Reset Original Settings, the program stabilized so that the user interface elements would appear and you could run a design. In any event, the problem has been fixed and no longer occurs in version 11.0.1.