Bug Fixes and Small Improvements – Graphics

Important Note – These are descriptions to changes implemented in version 10 and may not reflect current program behaviour.

  1. Dimension Overlap for Short Cantilevers (Bug 3247)

    For short cantilever spans, the design span dimension values shown below the beam overlapped, rendering them unreadable. Now, for beams with end spans less than 1/10 the length of the beam, the rightmost dimension is offset downwards to be visible, and for left end spans, the "0" is not shown.

  2. Load Envelope for Joist and Wall Area Loads (Bug 3320)

    For joists and wall studs, the magnitudes of area loads shown in the Load Envelope drawing of the Analysis diagrams were incorrectly multiplied by a factor equal to the joist spacing in the unit system chosen, e.g. 400 for metric or 16 for imperial. This has been corrected.

  3. Load Face Shown on Column Loads View Drawing (Bug 3155)

    In column load view, the program displayed b beside the loaded face of the member regardless of whether it is loaded on the b- face or d-face according the Load Face input in column view. This has been corrected and d is shown for d-face loading.

  4. Span Precision in Beam Drawing (Change 205)

    The number of decimal places shown on the beam drawing has been increased from one to two decimal places for inches and from two to three decimal places for feet, so that 1/4' appears as 0.25" rather than 0.3". For feet output, a value like 3.5" will appear as .292 rather than .29. This change has been applied to the drawings in both Beam view screen and in the Design Check output.

  5. Text Offset of Column Dimension Lines (Change 195)

    For the lines dimensioning columns, the text was not drawn in the middle of the dimension line, but was spaced away from the line. Now the text is drawn in the middle of the line.

  6. Truncation of Zeroes for Zero Moment Point (Change 201)

    In the Analysis diagram, the zero moment and zero shear locations were truncated to show whole numbers like 3 rather than 3.00 as is shown for all other points. This has been corrected

See Also

Sizer 10

NBC 2015, CSA O86-14 Updates 1 and 2, and S16-14

Cross-Laminated Timber (CLT) Design

Beam and Joist Hanger Database and Design

Steel Columns

Fire Design

Sloped Beam Loads Drawing

Bug Fixes and Small Improvements – Engineering Design

Bug Fixes and Small Improvements – Loads Analysis

Bug Fixes and Small Improvements – Input and Program Operation

Bug Fixes and Small Improvements – Output

Sizer 10.1

Sizer 10.2

Sizer 10.3