Previous Topic

Next Topic

Book Contents

Book Index

Load Combinations

Sizer generates a comprehensive set of load combinations according to provisions from the National Building Code (NBC) and its structural Commentaries given in the subtopics for each load type. The combinations include the following load types - live, dead, wind, snow, earthquake, sustained live, hydrostatic loads and dead loads due to soil.

In Concept mode, vertical load distribution is done independently for each load type, and the resulting loads are combined on each member.

Concentrated Load Combinations

The specified concentrated live load is considered to act in place of any live (occupancy) load for all load combinations (except patterns) specified by the code. The program verifies all of the load combinations it ordinarily does, plus those combinations derived by replacing the live occupancy loads in those combinations by the concentrated live load at one-foot increments along the member, creating a separate series of load combinations.

The main concentrated load combinations comprised of the moving concentrated load combined with the self-weight and the other non-live loads present on the beam are shown in the list of Load Combinations in the Analysis results. The "virtual" combinations created at one-foot intervals are only shown if they are critical for design.

In This Section

Load Combinations Generated

See Also

Loads and Analysis

Load Input

Load Options

Importance Factor

Self-weight

Pattern Loading

Concentrated Loads

Sloped Member Load Direction and Projection

Structural Analysis

Points Of Interest