The following provisions from Appendix N are implemented in Sizer
Appendix N.1.2: Specifies that loads and load combinations are from applicable building code or ASCE 7
Appendix N.2.1: Indicates that adjusted design values are from ASTM D5457 or from NDS using N 2.2
N.2.2: Indicates NDS design values are to be adjusted as per modification factors tables for each member type. These tables give the format conversion factor KF, and resistance factor φ and time effect factor λ that are also listed in N3.1, N3.2, and N3.3, respectively.
N3.1 - Gives format conversion factor KF for each design criterion. Also in Table 2.3.5.
In addition to Appendix N, the following following NDS provisions specific to LRFD are implemented in Sizer. Note that all other NDS provisions also apply to LRFD unless indicated as ASD-only.
1.4: LRFD is given as a permitted procedure
1.4.4: Load combination factors are to come from the governing design code, and load combinations and time effect factors λ are from Appendix N.
2.1.1.2: Mandates use of LRFD adjustment factors.
2.3.5 and Table 2.3.5; N.3.1 and Table N1: Specifies format conversion factor KF
2.3.6 and Table 2.3.6; N.3.2 and Table N2: Specifies resistance factor φ
2.3.7: Mandates time effect factor λ specified in N.3.3
4.3.3, 5.3.2, 7.3.2, 8.3.2, 10.3.2: Load duration factor CD indicated as ASD-only
4.3.14, 5.3.14, 7.3.8, 8.3.11, 10.3.10: Mandate format conversion factor KF for design criteria listed in Tables (see below)
4.3.15, 5.3.15, 7.3.9, 8.3.12, 10.3.11: Mandate resistance factor φ for design criteria listed in Tables (see below)
4.3.16, 5.3.16, 7.3.10, 8.3.13, 10.3.12: Mandate time effect factor λ specified in N.3.3 for design criteria listed in Tables (see below)
Tables 4.3, 5.3, 7.3, 8.3 and 10.3 – List design criteria applicable to format conversion factor KF, time effect factor λ, and resistance conversion factor φ